Technical Characteristics
-
Winding Operating Current
291.6 milliamperes ac maximum single component single primary
-
Body Length
0.650 inches maximum
-
Winding Operating Current
50.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Current
300.0 milliamperes dc maximum single component 2nd secondary
-
Frequency Rating
10.0 kilohertz nominal single component
-
Winding Operating Current
300.0 milliamperes dc maximum single component 3rd secondary
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
12.00 ac volts nominal single component single primary
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Winding Operating Voltage
4.00 ac volts nominal single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Maximum Operating Temp
130.0 deg celsius
-
Winding Operating Voltage
4.00 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
3.40 ac volts nominal single component 1st secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Body Outside Diameter
1.150 inches maximum
-
Unpackaged Unit Weight (Non-Core)
1.300 ounces
-
Winding Power Rating
3.5 volts-amperes single component single primary
-
Terminal Type And Quantity
12 pin