08P228093-02
Filters and Networks
FILTER,BAND PASS
08P228093-02
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Unthreaded Mounting Hole Diameter
0.128 inches nominal
-
Frequency Band Width Per Function
500.30 kilohertz 2nd band pass and 503.50 kilohertz 2nd band pass
-
Reference Frequency Per Function
501.9 single radio interference two phase to two phase
-
Overall Width
0.670 inches nominal
-
Body Surface Treatment
tin
-
Body Outside Diameter
0.437 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 2nd band pass and 60.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 60.0 minimum 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.750 inches nominal
-
Body Height
1.650 inches nominal
-
Overall Length
1.000 inches nominal
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Functional Terminal Type And Quantity
2 tab, solder lug input 1st function
-
Operating Temp Range
-30.0/+85.0 deg celsius
-
Insertion Loss At Reference Frequency Per Function In Decibels
5.5 1st band pass
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 60.0 minimum 1st band pass and 60.0 minimum 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
5.5 2nd band pass
-
Overall Height
2.562 inches nominal
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Inclosure Type
hermetically sealed
-
Maximum Dielectric Withstanding Dc Voltage
100.0 volts at sea level
-
Specified Frequencies Of Discrimination Per Function
499.20 kilohertz 2nd band pass and 500.30 kilohertz 2nd band pass and 503.50 kilohertz 2nd band pass and 505.30 kilohertz 2nd band pass
-
Functional Terminal Type And Quantity
2 tab, solder lug output 2nd function
-
Style Designator
round terminal/terminals on opposite surfaces
-
Distance Between Mounting Surface And Lower End
0.7212 inches nominal
-
Specified Frequencies Of Discrimination Per Function
500.30 kilohertz 1st band pass and 499.20 kilohertz 1st band pass and 503.50 kilohertz 1st band pass and 505.30 kilohertz 1st band pass
-
Reference Frequency Per Function
501.9 single radio interference pulses per second
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Frequency Band Width Per Function
500.30 kilohertz 1st band pass and 503.50 kilohertz 1st band pass