292413P1

Filters and Networks

FILTER,BAND PASS

292413P1

5915-01-154-3697

5915 - Filters and Networks

Bae Systems Information And

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Features

    switch control standard ttl logic input

  • Insertion Loss At Reference Frequency Per Function In Decibels

    14.0 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    50.00 megahertz 2nd band pass and 449.00 megahertz 2nd band pass and 337.00 megahertz 2nd band pass and 980.00 megahertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    14.0 1st band pass

  • Inclosure Type

    hermetically sealed

  • Frequency Band Width Per Function

    222.00 megahertz 1st band pass and 226.00 megahertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    12.5 minimum 2nd band pass and 15.5 maximum 2nd band pass

  • Frequency Band Width Per Function

    391.00 megahertz 2nd band pass and 395.00 megahertz 2nd band pass

  • Overall Height

    1.950 inches minimum and 2.070 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    254.00 megahertz 1st band pass and 191.00 megahertz 1st band pass and 30.00 megahertz 1st band pass and 555.00 megahertz 1st band pass

  • Style Designator

    rectangular terminal/terminals on three surfaces

  • Reference Frequency Per Function

    222.0 hercules no.5599.1 pulses per second

  • Overall Length

    5.340 inches minimum and 5.420 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    12.5 minimum 1st band pass and 15.5 maximum 1st band pass

  • Reference Frequency Per Function

    391.0 hercules no.5599.1 two phase to two phase

  • Mounting Facility Type And Quantity

    5 connector

  • Body Height

    1.230 inches minimum and 1.270 inches maximum

  • Voltage Standing Wave Ratio Per Function

    1.5 1st band pass

  • Body Width

    0.660 inches minimum and 0.700 inches maximum

  • Voltage Standing Wave Ratio Per Function

    2.0 2nd band pass

  • Mounting Facility Type And Quantity

    7 terminal

  • Body Length

    4.980 inches minimum and 5.020 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.