AM1-A8-30-20

Circuit Breakers

CIRCUIT BREAKER

AM1-A8-30-20

5925-01-155-9828

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Frequency In Hertz

    50.0 or

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Inclosure Protection Type For Which Designed

    moisture resistant and

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and

  • Body Style

    12a single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Iii Storage Type

    general purpose warehouse

  • Boss Height

    0.140 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and

  • Case Material

    plastic

  • Body Width

    0.780 inches maximum

  • Body Width

    0.730 inches minimum and

  • Body Length

    2.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...