G330168-9

Circuit Breakers

CIRCUIT BREAKER

G330168-9

5925-01-155-9828

5925 - Circuit Breakers

Itt Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Frequency In Hertz

    50.0 or

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Inclosure Protection Type For Which Designed

    moisture resistant and

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and

  • Body Style

    12a single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Iii Storage Type

    general purpose warehouse

  • Boss Height

    0.140 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and

  • Case Material

    plastic

  • Body Width

    0.780 inches maximum

  • Body Width

    0.730 inches minimum and

  • Body Length

    2.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.