3522 500 25032
Circuit Breakers
CIRCUIT BREAKER
3522 500 25032
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches nominal
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Nominal Thread Size
0.138 inches
-
Ultimate Trip Time Per Pole In Seconds
800.000 maximum all locations
-
Switch Location And Position Designation
external at pole one
-
Special Features
anti-flashover barrier between poles
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Length
3.550 inches nominal
-
Mounting Surface To Terminal End Distance
3.550 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Boss Height
0.220 inches nominal
-
~1
locations and 18.000 maximum at 400 pct all locat
-
Trip Delay Time In Seconds Per Rated Continuous Current
800.000 maximum at 125 pct all locations and 20.000 minimum at 200 pct all locations and 130.000 maximum at 200 pct all locations and 4.000 minimum at 400 pct all locations and 70.000 minimum at 125 pct all locations and 0.012 minimum at 1000 pct all
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations and 480.0 ac all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Body Width
3.108 inches maximum
-
Auxiliary Switch Function And Quantity
1 control
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Actuator Function
reset
-
Switch Terminal Type
tab, solder lug
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
1.026 inches nominal
-
Switch Current Rating And Type In Amps
10.0 ac
-
Trip Release Characteristic
time delay all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Body Length
5.125 inches nominal