Winding Operating Voltage
105.00 ac volts nominal single component 2nd primary and 115.00 ac volts nominal single component 2nd primary and 93.00 ac volts nominal single component 2nd primary and 125.00 ac volts nominal single component 2nd primary
-
Mounting Method
bracket single group and slot single group
-
Body Length
6.570 inches maximum
-
Winding Function And Quantity
2 primary single component and 1 secondary single component
-
Winding Operating Current
22.0 amperes dc nominal single component single secondary
-
Maximum Transformer Power Rating
2.65 kilovolt-ampere single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
4.280 inches nominal single mounting facility single center group
-
Inclosure Type
fully inclosed
-
Frequency Rating
48.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Operating Voltage
26.50 dc volts nominal single component single secondary
-
Mounting Slot Width
0.390 inches nominal single group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Reliability Indicator
not established
-
Maximum Operating Temp
55.0 deg celsius
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
5.320 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Overall Width
6.360 inches maximum
-
Terminal Type And Quantity
11 tab, solder lug