RF10548-1
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
RF10548-1
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
62.0 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Power Line Frequency Rating Per Function In Hertz
62.0 2nd radio interference
-
Body Width
6.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Overall Length
5.000 inches nominal
-
Operating Temp Range
-55.0/+65.0 deg celsius
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function and 600.0 volts dc 2nd radio interference 2nd function
-
Body Length
4.000 inches nominal
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
80.0 and 30.0 and 80.0
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Voltage Drop Per Function
2.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
2.0 volts ac 1st radio interference
-
Inclosure Type
encased
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference 1st function and 600.0 volts dc 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
10.0 1st radio interference
-
Input Terminal Manufacturer Code
96906
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Overall Height
3.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
5.000 inches nominal
-
Maximum Temp Rise
20.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
0.05 and 0.3 and 1000.0
-
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function and 2 threaded stud output 2nd function
-
Operating Current Rating Per Function In Amps
10.0 2nd radio interference
-
Input Terminal Identification
ms3112e-12-3p