CD1B3U100125-1

Circuit Breakers

CIRCUIT BREAKER

CD1B3U100125-1

5925-01-157-4446

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Style

    single pole type

  • Mounting Slot Width

    0.178 inches nominal

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 3.557 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Surface To Terminal End Distance

    3.229 inches minimum and 3.249 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 unthreaded hole and 1 slot

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 40.000 maximum at 200 pct

  • Actuator Function

    trip-reset

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • End Item Identification

    used onboard 32 ft. coast guard vessels

  • Pole Quantity

    1

  • Arc Quenching Method

    air

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...