CDA 8I

Circuit Breakers

CIRCUIT BREAKER

CDA 8I

5925-01-157-4604

5925 - Circuit Breakers

Texas Instruments Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    16.3 millimeters nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location and 30.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 600.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Nominal Thread Size

    0.164 inches

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    39.98 millimeters nominal

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Mounting Surface To Terminal End Distance

    32.5 millimeters nominal

  • Reset Method

    automatic

  • Case Material

    plastic

  • End Item Identification

    3805-01-126-7915

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Body Width

    24.14 millimeters nominal

  • Thread Series Designator

    unc

  • Storage Type

    general purpose warehouse

  • Overall Length

    50.8 millimeters nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac single location and 8.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...