17321-0-124 MOD4
Switches
SWITCH,THERMOSTATIC
17321-0-124 MOD4
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc all threaded hole
-
Contact Adjustability
deactuation point adjustable, preset and actuation point adjustable, preset
-
Nominal Thread Size
0.164 inches all threaded hole
-
Contact Voltage Rating In Volts
120.0 ac at sea level second voltage
-
Contact Adjustment Range
-100.00/+400.00 actuation point degrees fahrenheit and -100.00/+400.00 deactuation point degrees fahrenheit
-
Overall Length
4.906 inches nominal
-
Media For Which Designed
gas or liquid
-
Style Designator
cylindrical w/flange
-
Contact Load Current Rating
2.0 amperes resistive load fourth voltage
-
Contact Voltage Rating In Volts
28.0 dc at sea level fourth voltage
-
Body Length
3.593 inches nominal
-
Terminal Type
wire lead
-
Contact Load Current Rating
5.0 amperes resistive load first voltage
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
115.0 dc at sea level third voltage
-
Thread Class
2b all threaded hole
-
Features Provided
tamper proof cap
-
Contact Stimulus Rating
124.00 actuation point nominal degrees fahrenheit and 119.00 deactuation point nominal degrees fahrenheit
-
Longest Vertical Distance Between Mounting Centers
0.937 inches nominal
-
Body Diameter
0.618 inches minimum and 0.625 inches maximum
-
Longest Horizontal Distance Between Mounting Centers
1.082 inches nominal
-
Mounting Method
flange and threaded hole
-
Contact Voltage Rating In Volts
240.0 ac at sea level first voltage
-
Mounting Facility Pattern
isosceles triangle
-
Shortest Horizontal Distance Between Mounting Centers
0.540 inches nominal
-
Thread Quantity Per Inch
32 all threaded hole
-
Overall Diameter
1.750 inches nominal
-
Temp Sensing Element Type
expanding shell
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
Contact Load Current Rating
10.0 amperes resistive load second voltage
-
Contact Load Current Rating
2.0 amperes resistive load third voltage
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action