SM-A-838216-3

Filters and Networks

FILTER,BAND PASS

SM-A-838216-3

5915-01-158-3758

5915 - Filters and Networks

Aeroflex Laboratories Inc

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Inclosure Type

    hermetically sealed

  • Body Height

    0.580 inches maximum

  • Reference Frequency Per Function

    15.056 single radio interference hertz

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    8.816 kilohertz 5th band pass and 8.928 kilohertz 5th band pass and 9.312 kilohertz 5th band pass and 9.424 kilohertz 5th band pass

  • Overall Height

    0.750 inches maximum

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Body Width

    1.875 inches maximum

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Unpackaged Unit Weight

    6.000 ounces

  • Reference Frequency Per Function

    9.12 single radio interference three phase to two phase

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and 3.0 minimum 1st band pass and 3.0 minimum 3rd band pass and 3.0 minimum 4th band pass and 3.0 minimum 5th band pass and 30.0 maximum 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    13.904 kilohertz 3rd band pass and 13.216 kilohertz 3rd band pass and 13.36 kilohertz 3rd band pass and 14.048 kilohertz 3rd band pass

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Operating Temp Range

    -29.0/+85.0 deg celsius

  • Reference Frequency Per Function

    11.152 single radio interference pulses per second

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Reference Frequency Per Function

    13.632 single radio interference two phase to three phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 4th band pass

  • Reference Frequency Per Function

    12.32 single radio interference two phase to two phase

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 5th band pass

  • Frequency Band Width Per Function

    12.08 kilohertz 2nd band pass and 12.56 kilohertz 2nd band pass

  • Mounting Facility Type And Quantity

    12 pin

  • Frequency Band Width Per Function

    10.944 kilohertz 1st band pass and 11.36 kilohertz 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Frequency Band Width Per Function

    8.928 kilohertz 5th band pass and 9.312 kilohertz 5th band pass

  • Body Surface Treatment

    tin

  • Frequency Band Width Per Function

    14.752 kilohertz 4th band pass and 15.344 kilohertz 4th band pass

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Special Features

    five filtered functions

  • Frequency Band Width Per Function

    13.36 kilohertz 3rd band pass and 13.904 kilohertz 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    10.944 kilohertz 1st band pass and 10.816 kilohertz 1st band pass and 11.36 kilohertz 1st band pass and 11.488 kilohertz 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Body Material

    metal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Body Length

    3.035 inches maximum

  • Style Designator

    rectangular terminal/terminals on one surface

  • Specified Frequencies Of Discrimination Per Function

    15.344 kilohertz 4th band pass and 14.608 kilohertz 4th band pass and 14.752 kilohertz 4th band pass and 15.52 kilohertz 4th band pass

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    12.56 kilohertz 2nd band pass and 12.08 kilohertz 2nd band pass and 11.952 kilohertz 2nd band pass and 12.704 kilohertz 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...