CD1-B3-DU0070-02C

Circuit Breakers

CIRCUIT BREAKER

CD1-B3-DU0070-02C

5925-01-158-4510

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.220 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc single location

  • Unpackaged Unit Weight

    9.000 ounces

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes dc single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • End Item Identification

    lav, anti-tank

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Special Features

    weapon system essential

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.610 inches nominal

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    5.800 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Width

    1.013 inches nominal

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...