AM4S-Z1001-1W

Circuit Breakers

CIRCUIT BREAKER

AM4S-Z1001-1W

5925-01-159-6595

5925 - Circuit Breakers

Heinemann Electric Canada Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac third location

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Frequency In Hertz

    50.0 second location or 400.0 second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Unpackaged Unit Weight

    12.500 ounces

  • Circuit Protection Type

    undervoltage fourth location

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Boss Height

    0.140 inches minimum and 0.150 inches maximum

  • Frequency In Hertz

    50.0 first location or 400.0 first location

  • Terminal Type And Quantity

    8 threaded stud

  • Internal Trip Release Configuration

    series trip second location

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac second location

  • Internal Trip Release Configuration

    series trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic-hydraulic first location

  • Frequency In Hertz

    50.0 third location or 400.0 third location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac first location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Release Method

    magnetic-hydraulic second location

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    20.0 dc fourth location

  • Trip Release Method

    magnetic-hydraulic third location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...