CD4-Z121-1

Circuit Breakers

CIRCUIT BREAKER

CD4-Z121-1

5925-01-159-6596

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc fourth location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 third location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    4 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct first location and 1.000 maximum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct third location and 1.000 maximum at 200 pct

  • Special Features

    high inrush protection poles one,two and three

  • Frequency In Hertz

    400.0 second location

  • Unpackaged Unit Weight

    2.438 pounds

  • Terminal Type And Quantity

    8 threaded stud

  • Thread Series Designator

    unc

  • Frequency In Hertz

    400.0 third location

  • Frequency In Hertz

    400.0 first location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct second location and 1.000 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 fourth location

  • Trip Release Characteristic

    time delay second location

  • Trip Release Characteristic

    instantaneous fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc fourth location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac second location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Boss Height

    0.218 inches nominal

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Body Height

    3.474 inches minimum and 3.504 inches maximum

  • Body Width

    4.128 inches nominal

  • Body Length

    5.844 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...