29-512113-1

Circuit Breakers

CIRCUIT BREAKER

29-512113-1

5925-01-159-6599

5925 - Circuit Breakers

General Dynamics C4 Systems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Switch Terminal Type

    tab, solder lug

  • Special Features

    high inrush pole one only and pole four is a remote voltage trip application

  • Mounting Surface To Terminal End Distance

    2.403 inches minimum and 2.533 inches maximum

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Unpackaged Unit Weight

    12.312 pounds

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Internal Trip Release Configuration

    series trip fourth location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Switch Contact Arrangement

    single pole, double throw

  • Body Width

    2.960 inches minimum and 3.040 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct fourth location and 1.500 maximum at 200 pct fourth location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Pole Quantity

    4

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc fourth location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Frequency In Hertz

    400.0 third location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Features Provided

    high inrush protection

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Terminal Type And Quantity

    9 threaded stud

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Internal Trip Release Configuration

    series trip third location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Frequency In Hertz

    400.0 second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Test Data Document

    04655-29-512113 standard (includes industry or association standards, individual manufactureer standards, etc.).

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...