CD5-Z13-1
Circuit Breakers
CIRCUIT BREAKER
CD5-Z13-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc
-
Circuit Protection Type
overcurrent
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0
-
External Actuator Linkage Arrangement
one,two,three,four,and five linked
-
Internal Trip Release Configuration
series trip
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 10.500 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Terminal Type
tab,solder lug
-
Special Features
high inrush pole one only and pole five is a remote voltage trip application
-
Test Data Document
04655-29-512129 standard
-
Thread Series Designator
unc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Frequency In Hertz
400.0
-
Unpackaged Unit Weight
3.000 pounds
-
Terminal Type And Quantity
11 threaded stud
-
Body Width
5.160 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
-
Pole Quantity
5
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
10 threaded hole
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Features Provided
high inrush protection
-
Body Length
5.844 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Switch Contact Arrangement
single pole,double throw
-
Fragility Factor
moderately rugged
-
Boss Height
0.218 inches nominal
-
Mounting Surface To Terminal End Distance
2.609 inches nominal
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
instantaneouss
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
5 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Auxiliary Switch Function And Quantity
1 alarm
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 minimum at 200 pct and 1.000 maximum at 200 pct
-
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc