APL11-1REC4-20102-8

Circuit Breakers

CIRCUIT BREAKER

APL11-1REC4-20102-8

5925-01-159-6603

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Body Width

    1.515 inches maximum

  • Case Material

    plastic

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.399 inches minimum and 2.543 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct and 10.000 maximum at 200 pct

  • Body Length

    2.480 inches minimum and 2.520 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct

  • Switch Terminal Type

    tab,solder lug

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    7.400 ounces

  • Thread Series Designator

    unc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...