1001319

Circuit Breakers

CIRCUIT BREAKER

1001319

5925-01-159-6605

5925 - Circuit Breakers

Tld Ace Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Bushing Length

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Width

    0.110 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Thread Quantity Per Inch

    27

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    2.300 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.790 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nonturn Device Length

    0.060 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    1.410 ounces

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    20.0 ac single location and 20.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 65.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.570 inches nominal

  • Nonturn Device Radius

    0.370 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    1.140 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...