CD4-Z296-2W

Circuit Breakers

CIRCUIT BREAKER

CD4-Z296-2W

5925-01-159-6609

5925 - Circuit Breakers

Heinemann Electric Canada Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    49956-g166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Trip Release Method

    magnetic-hydraulic third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac fourth location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • Frequency In Hertz

    400.0 third location

  • Trip Release Method

    magnetic first location

  • Special Features

    four terminals on pole one

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 fourth location

  • Manual Actuator Type And Quantity

    4 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac second location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct third location and 10.000 maximum at 200 pct third location

  • Trip Release Characteristic

    instantaneous first location

  • Trip Release Characteristic

    time delay fourth location

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Frequency In Hertz

    400.0 second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Mounting Facility Type And Quantity

    8 threaded hole and 8 slot

  • Trip Release Method

    magnetic-hydraulic fourth location

  • Boss Height

    0.218 inches nominal

  • Trip Release Method

    magnetic-hydraulic second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct fourth location and 10.000 maximum at 200 pct fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Body Length

    5.844 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Operating Voltage Type And Rating Per Pole In Volts

    107.0 dc first location

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac third location

  • Actuator Function

    trip-reset

  • Body Width

    3.096 inches nominal

  • Frequency In Hertz

    400.0 fourth location

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Circuit Protection Type

    overcurrent fourth location

  • Circuit Protection Type

    undervoltage first location

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac fourth location

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...