AM4-Z86-1
Circuit Breakers
CIRCUIT BREAKER
AM4-Z86-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Body Width
2.960 inches minimum and 3.040 inches maximum
-
Case Material
plastic
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Features Provided
high inrush protection
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc
-
Trip Release Method
magnetic-hydraulic
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Terminal Type
tab,solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Special Features
high inrush pole one only
-
Test Data Document
04655-29-512113 standard
-
Thread Series Designator
unc
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Switch Contact Arrangement
single pole,double throw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
2.403 inches minimum and 2.533 inches maximum
-
Pole Quantity
4
-
Mounting Facility Type And Quantity
8 threaded hole
-
Special Handling Feature
magnetic
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
4 toggle
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one,two,three,and four linked
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.500 maximum at 200 pct
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct
-
Frequency In Hertz
400.0
-
Unpackaged Unit Weight
12.312 pounds
-
Terminal Type And Quantity
9 threaded stud