29-512113-2

Circuit Breakers

CIRCUIT BREAKER

29-512113-2

5925-01-160-0065

5925 - Circuit Breakers

General Dynamics C4 Systems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    2.960 inches minimum and 3.040 inches maximum

  • Case Material

    plastic

  • Switch Contact Arrangement

    double pole, double throw

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac third location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.533 inches maximum

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Circuit Protection Type

    overcurrent second location

  • Circuit Protection Type

    overcurrent third location

  • Circuit Protection Type

    overvoltage fourth location

  • Trip Release Method

    magnetic-hydraulic second location

  • Trip Release Method

    magnetic-hydraulic third location

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Trip Release Method

    magnetic-hydraulic first location

  • Trip Release Characteristic

    instantaneous fourth location

  • Trip Release Characteristic

    time delay second location

  • Trip Release Characteristic

    time delay third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct second location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    8 threaded stud

  • Manual Actuator Type And Quantity

    4 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct third location

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    12.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People