996302-6

Circuit Breakers

CIRCUIT BREAKER

996302-6

5925-01-160-0069

5925 - Circuit Breakers

Raytheon Technical Services Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Frequency In Hertz

    400.0 first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    4 toggle

  • Trip Release Method

    magnetic fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Frequency In Hertz

    400.0 third location

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Trip Release Method

    magnetic-hydraulic third location

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Trip Release Method

    magnetic-hydraulic second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Trip Release Characteristic

    instantaneous fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Trip Release Characteristic

    time delay third location

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Method

    magnetic-hydraulic first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Circuit Protection Type

    overvoltage fourth location

  • Frequency In Hertz

    400.0 second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Trip Release Characteristic

    time delay second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Terminal Type And Quantity

    8 threaded stud

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Circuit Protection Type

    overcurrent third location

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent second location

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...