APGN666-7985-3

Circuit Breakers

CIRCUIT BREAKER

APGN666-7985-3

5925-01-160-2856

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Iii Nonturn Device Diameter

    0.161 inches maximum

  • Mounting Surface To Terminal End Distance

    2.240 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.500 inches

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Terminal Type And Quantity

    6 tab w/screw

  • Bushing Length

    0.490 inches maximum

  • Body Length

    2.050 inches maximum

  • Body Width

    2.270 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Iii Nonturn Device Location

    at 12 oclock

  • Iii Nonturn Device Radius

    0.661 inches maximum

  • Iii Nonturn Device Length

    0.150 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Iii End Item Identification

    1450-01-119-4987

  • Pole Quantity

    3

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Frequency In Hertz

    47.0 or

  • Frequency In Hertz

    63.0 all locations

  • Thread Series Designator

    un

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...