2567-249
Circuit Breakers
CIRCUIT BREAKER
2567-249
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Location And Position Designation
external at pole one
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Method
magnetic-hydraulic first location
-
Arc Quenching Method
magnetic blowout
-
Circuit Protection Type
overvoltage second location
-
Body Length
5.769 inches minimum and 5.831 inches maximum
-
Trip Release Characteristic
instantaneous second location
-
Manual Actuator Type And Quantity
2 toggle
-
Frequency In Hertz
50.0 first location or 60.0 first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct first location and 70.000 maximum at 200 pct first location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Nominal Thread Size
0.138 inches
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.719 inches minimum and 2.781 inches maximum
-
Unpackaged Unit Weight
11.000 ounces
-
Center To Center Distance Between Terminals Parallel To Width
0.995 inches minimum and 1.057 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 second location
-
External Actuator Linkage Arrangement
one and two linked
-
Features Provided
high inrush protection
-
Body Width
2.041 inches minimum and 2.103 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Inclosure Protection Type For Which Designed
dustproof
-
Internal Trip Release Configuration
relay trip second location
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Switch Terminal Type
turret
-
Circuit Protection Type
overcurrent first location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.995 inches minimum and 1.057 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole
-
Boss Height
0.209 inches minimum and 0.229 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.516 inches minimum and 3.578 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
3.172 inches minimum and 3.265 inches maximum
-
Body Style
multipole-multiple actuator type
-
Internal Trip Release Configuration
series trip first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location
-
Trip Release Characteristic
time delay first location