2567-249-00

Circuit Breakers

CIRCUIT BREAKER

2567-249-00

5925-01-161-2945

5925 - Circuit Breakers

Lorain Electronics Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Location And Position Designation

    external at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic-hydraulic first location

  • Arc Quenching Method

    magnetic blowout

  • Circuit Protection Type

    overvoltage second location

  • Body Length

    5.769 inches minimum and 5.831 inches maximum

  • Trip Release Characteristic

    instantaneous second location

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    50.0 first location or 60.0 first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct first location and 70.000 maximum at 200 pct first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Nominal Thread Size

    0.138 inches

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.719 inches minimum and 2.781 inches maximum

  • Unpackaged Unit Weight

    11.000 ounces

  • Center To Center Distance Between Terminals Parallel To Width

    0.995 inches minimum and 1.057 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 second location

  • External Actuator Linkage Arrangement

    one and two linked

  • Features Provided

    high inrush protection

  • Body Width

    2.041 inches minimum and 2.103 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Inclosure Protection Type For Which Designed

    dustproof

  • Internal Trip Release Configuration

    relay trip second location

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Switch Terminal Type

    turret

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.995 inches minimum and 1.057 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.516 inches minimum and 3.578 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.265 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...