299-1-7139-1

Circuit Breakers

CIRCUIT BREAKER

299-1-7139-1

5925-01-162-9160

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Case Material

    plastic

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct and 20.000 maximum at 200 pct single location

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Length

    4.735 inches minimum and 4.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.535 inches minimum and 3.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.735 inches minimum and 2.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.205 inches minimum and 0.265 inches maximum

  • Mounting Surface To Terminal End Distance

    3.535 inches minimum and 3.565 inches maximum

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip w/dual rating single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    0.562 pounds

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.