5189636-005

Circuit Breakers

CIRCUIT BREAKER

5189636-005

5925-01-163-8562

5925 - Circuit Breakers

Naval Sea Systems Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    17.000 minimum at 200 pct all locations and 59.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    thermal-magnetic all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Bushing Length

    0.145 inches minimum and 0.155 inches maximum

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    sand resistant and corrosion resistant and dusttight and shock resistant and explosion proof

  • Circuit Protection Type

    overcurrent all locations

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Body Height

    2.470 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.870 inches nominal

  • Body Width

    2.270 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Body Length

    2.200 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.