6B12-30
Coils and Transformers
TRANSFORMER,POWER
6B12-30
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
3.500 inches minimum and 3.620 inches maximum
-
Unpackaged Unit Weight
2.200 pounds
-
Maximum Transformer Power Rating
30.0 volt-ampere
-
Input-Output Phase Relationship
single phase to single phase
-
Frequency Rating
50.0 hertz minimum and 65.0 hertz maximum
-
Overall Height
3.000 inches minimum and 3.120 inches maximum
-
Terminal Type And Quantity
6 tab,solder lug
-
Winding Operating Voltage
12.00 ac volts nominal
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Current
2.5 amperes ac nominal
-
Cubic Measure
23.7 cubic inches
-
Winding Function And Quantity
1 primary and 2 secondary
-
Mounting Method
bracket and unthreaded hole
-
Mounting Facility Quantity
2
-
Inclosure Type
open
-
Distance Between Mounting Facility Centers
3.060 inches minimum and 3.180 inches maximum
-
Maximum Operating Temp
80.0 deg celsius
-
Mounting Hole Diameter
0.180 inches nominal
-
Overall Width
2.180 inches maximum
-
Reliability Indicator
not established