5189196-003

Circuit Breakers

CIRCUIT BREAKER

5189196-003

5925-01-166-7119

5925 - Circuit Breakers

Naval Sea Systems Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 screw and 2 wire hook

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Unpackaged Unit Weight

    1.800 ounces

  • Mounting Surface To Terminal End Distance

    1.750 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    wire hook

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and hermetically sealed

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.843 inches minimum and 0.906 inches maximum

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Body Width

    0.625 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Tolerance Class

    2a external

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 0.700 maximum at 200 pct single location

  • Switch Location And Position Designation

    internal at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...