AP6-IRC-5995-005

Circuit Breakers

CIRCUIT BREAKER

AP6-IRC-5995-005

5925-01-166-7121

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

  • Inclosure Protection Type For Which Designed

    shockproof and hermetically sealed and vibrationproof

  • Switch Location And Position Designation

    internal at pole one

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Unpackaged Unit Weight

    1.800 ounces

  • Mounting Surface To Terminal End Distance

    1.750 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug and 2 wire hook

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 0.700 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    wire hook

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...