5189636-004
Circuit Breakers
CIRCUIT BREAKER
5189636-004
Hughes Missile Systems Co - Pomona
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
14.000 minimum at 200 pct all locations and 52.000 maximum at 200 pct all locations
-
Frequency In Hertz
400.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Width
2.200 inches maximum
-
Body Length
2.270 inches maximum
-
Terminal Type And Quantity
6 tab w/screw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 ac all locations
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Inclosure Protection Type For Which Designed
sand resistant and dusttight and shock resistant and explosion proof and corrosion resistant
-
Trip Release Method
thermal-magnetic all locations
-
Manual Actuator Type And Quantity
1 push-pull
-
Bushing Length
0.145 inches minimum and 0.155 inches maximum
-
Actuator Position Designation
at pole two
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Facility Type And Quantity
6 threaded hole