203-2-2-62F-302-4-1-1-A

Circuit Breakers

CIRCUIT BREAKER

203-2-2-62F-302-4-1-1-A

5925-01-166-7562

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    external at pole one

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Special Features

    handle equipped w/neon bulb; flush mtg hardware incl

  • Frequency In Hertz

    50.0 or 60.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct and 0.009 minimum at 500 pct and 0.900 maximum at 500 pct single location

  • Switch Terminal Type

    turret

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Body Width

    0.920 inches nominal

  • Case Material

    plastic

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum and 600.000 maximum single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Style

    10a single pole type

  • Body Height

    1.770 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.125 inches nominal

  • Mounting Facility Type And Quantity

    2 clip

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...