921672

Circuit Breakers

CIRCUIT BREAKER

921672

5925-01-167-7747

5925 - Circuit Breakers

Kollmorgen Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    shockproof and fungus proof and vibrationproof

  • Body Length

    0.781 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Width

    1.840 inches maximum

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Terminal Type And Quantity

    6 screw

  • Specification/Standard Data

    96906-ms14154 government standard

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.593 inches minimum and 0.655 inches maximum

  • Body Height

    1.381 inches maximum

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...