M55629/1-241

Circuit Breakers

CIRCUIT BREAKER

M55629/1-241

5925-01-168-7370

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and vibration resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Specification/Standard Data

    81349-mil-c-55629/1 government specification

  • Body Style

    single pole type

  • Body Length

    2.510 inches maximum

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes dc single location

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct single location and 1.400 maximum at 200 pct single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Trip Release Method

    magnetic single location

  • Body Width

    0.730 inches minimum and 0.780 inches maximum

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...