83246-2
Switches
SWITCH,PRESSURE
83246-2
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Contact Load Current Rating
4.0 amperes resistive load single voltage
-
Mounting Facility Pattern
four position rectangular
-
Contact Action Stimulus
increase
-
Outside Diameter
0.621 inches minimum second connection and 0.623 inches maximum second connection
-
Terminal Type
connector, receptacle
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 203.0 deg fahrenheit maximum
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Longest Horizontal Distance Between Mounting Centers
2.995 inches minimum and 3.005 inches maximum
-
Contact Stimulus Rating
0.80 actuation point maximum gallons per minute and 0.40 actuation point minimum gallons per minute and 0.20 deactuation point minimum gallons per minute and 0.50 deactuation point maximum gallons per minute
-
Mounting Method
unthreaded hole
-
Media For Which Designed
liquid
-
Pressure Connector Type
solder cup, unthreaded internal first connection
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Overall Length
1.625 inches nominal
-
Overall Height
2.125 inches nominal
-
Features Provided
hermetically sealed case
-
Unthreaded Mounting Hole Diameter
0.195 inches minimum and 0.201 inches maximum
-
Inside Diameter
0.625 inches minimum first connection and 0.629 inches maximum first connection
-
Pressure Connector Type
grooved, unthreaded external second connection
-
Overall Width
3.375 inches nominal
-
Longest Vertical Distance Between Mounting Centers
1.745 inches minimum and 1.755 inches maximum
-
Proof Pressure
270.00 pounds per square inch gage
-
Style Designator
rectangular
-
Body Length
1.250 inches nominal
-
Body Height
2.125 inches nominal
-
Pressure Switch Type
gage
-
Sensing Element Burst Pressure
450.00 pounds per square inch gage