203-2-1-50-101-4-1-2
Circuit Breakers
CIRCUIT BREAKER
203-2-1-50-101-4-1-2
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Iii Unpackaged Unit Weight
2.100 ounces
-
Body Style
10a single pole type
-
Case Material
plastic
-
Boss Height
0.125 inches nominal
-
Pole Quantity
1
-
Iii Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 maximum at 200 pct single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Length
2.000 inches nominal
-
Body Width
0.920 inches nominal
-
Body Height
1.770 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 clip
-
Circuit Protection Type
overcurrent single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle