AP-116-1-7-2-202

Circuit Breakers

CIRCUIT BREAKER

AP-116-1-7-2-202

5925-01-170-5764

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    1.937 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • End Item Identification

    5865-01-004-1098 counter measure

  • Body Length

    1.562 inches maximum

  • Terminal Type And Quantity

    6 screw

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Thread Series Designator

    unef

  • Unpackaged Unit Weight

    5.400 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...