219-2-4505-2

Circuit Breakers

CIRCUIT BREAKER

219-2-4505-2

5925-01-171-1671

5925 - Circuit Breakers

Vdo Control Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 nominal at 500 pct first location

  • Switch Terminal Type

    turret

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    3.765 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Terminal Type And Quantity

    5 threaded stud

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Body Width

    2.063 inches nominal

  • Unpackaged Unit Weight

    11.000 ounces

  • Boss Height

    0.220 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    4.750 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Internal Trip Release Configuration

    shunt trip first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 nominal at 400 pct second location

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Location And Position Designation

    external at pole one

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip second location

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...