APGN-66-1REC3-7026-7

Circuit Breakers

CIRCUIT BREAKER

APGN-66-1REC3-7026-7

5925-01-171-3637

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    un

  • Switch Terminal Type

    quick disconnect, male

  • Nonturn Device Radius

    0.656 inches nominal

  • Body Width

    1.500 inches nominal

  • Nonturn Device Length

    0.130 inches nominal

  • Terminal Type And Quantity

    4 tab w/screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Body Style

    multipole-single actuator type

  • Unpackaged Unit Weight

    6.000 ounces

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 3500.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Bushing Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and moisture resistant and vibration resistant and hermetically sealed

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Switch Location And Position Designation

    internal at pole one and internal at pole two

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Case Material

    plastic and metal

  • Nonturn Device Location

    at 12 oclock

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...