MIL-C-39019/6

Circuit Breakers

CIRCUIT BREAKER

MIL-C-39019/6

5925-01-171-8702

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • ~1

    data on certain environmental and performanc

  • Bushing Length

    0.380 inches maximum

  • Features Provided

    high inrush protection

  • Terminal Type And Quantity

    6 wire hook

  • Specification/Standard Data

    81349-mil-c-39019/6 government specification

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations and 15.0 amperes dc all locations

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Length

    1.562 inches maximum

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.937 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...