6752-12-20
Circuit Breakers
CIRCUIT BREAKER
6752-12-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
sand resistant and dusttight and corrosion resistant and fungus resistant and shock resistant and humidity resistant and vibration resistant and explosion resistant
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Surface To Terminal End Distance
2.340 inches minimum and 2.400 inches maximum
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location
-
Terminal Type And Quantity
2 tab w/screw
-
Body Width
0.750 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.900 inches minimum and 0.910 inches maximum
-
Bushing Length
0.250 inches minimum and 0.265 inches maximum
-
Case Material
plastic
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 ac single location and 6000.0 dc single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Unpackaged Unit Weight
3.250 ounces
-
Pole Quantity
1
-
Trip Delay Time In Seconds Per Rated Continuous Current
19.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
-
Body Length
2.189 inches maximum
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.160 inches minimum and 2.220 inches maximum
-
Trip Release Method
thermal-magnetic single location
-
Specification/Standard Data
53711-5433036 manufacturers source control