CF1-H3-U-15-A-1

Circuit Breakers

CIRCUIT BREAKER

CF1-H3-U-15-A-1

5925-01-172-9542

5925 - Circuit Breakers

U S Dept Of Transportation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 1000.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

  • Body Style

    8a single pole type

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Body Width

    0.994 inches minimum and 1.058 inches maximum

  • Body Height

    2.577 inches minimum and 2.641 inches maximum

  • Case Material

    plastic

  • End Item Identification

    engine generator (eg)

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole and 2 slot

  • Trip Release Method

    magnetic-hydraulic single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof

  • Terminal Type And Quantity

    4 screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...