MIS-31509-231

Circuit Breakers

CIRCUIT BREAKER

MIS-31509-231

5925-01-174-0335

5925 - Circuit Breakers

U S Army Aviation And Missile

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    1.562 inches maximum

  • Unpackaged Unit Weight

    100.0 grams

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations and 500.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and shock resistant and salt spray proof and vibration resistant

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • Features Provided

    high inrush protection

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations and 5.0 amperes dc all locations

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Terminal Type And Quantity

    4 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...