UPGX-112-7079-1

Circuit Breakers

CIRCUIT BREAKER

UPGX-112-7079-1

5925-01-174-8585

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Body Width

    2.260 inches minimum and 2.270 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    8 quick disconnect, male

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Internal Trip Release Configuration

    series/relay trip first location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.647 inches minimum and 1.677 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    250.0 ac nominal first location

  • Trip Release Characteristic

    instantaneous first location

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Trip Release Characteristic

    time delay second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Internal Trip Release Configuration

    series trip third location

  • Mounting Surface To Terminal End Distance

    2.390 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Inclosure Protection Type For Which Designed

    moisture resistant and corrosion resistant and shock resistant and vibration resistant

  • Trip Release Duty Cycle

    continuous first location

  • Special Features

    rocker actuator attached to circuit breaker handle

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.