APGN-6-1REC6-9382-4

Circuit Breakers

CIRCUIT BREAKER

APGN-6-1REC6-9382-4

5925-01-175-5053

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.4752 to 0.4787 inches

  • Bushing Length

    0.625 inches nominal

  • Body Length

    2.000 inches nominal

  • Body Width

    0.750 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Length

    0.130 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • End Item Identification

    2350-01-089-1261

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 8.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Unpackaged Unit Weight

    3.000 ounces

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    2a single pole type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Nonturn Device Radius

    0.656 inches nominal

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    1

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.500 inches

  • Switch Location And Position Designation

    internal at pole one

  • Switch Terminal Type

    quick disconnect, male

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Thread Series Designator

    un

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...