TW-64749
Coils and Transformers
TRANSFORMER,POWER
TW-64749
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Transformer Winding Connection Type
wye-wye
-
Body Length
3.000 inches maximum
-
Winding Operating Current
9.0 milliamperes ac maximum single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.630 inches nominal single mounting facility single center group
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Current
1.0 amperes dc maximum single component single secondary
-
Unpackaged Unit Weight (Non-Core)
9.000 ounces
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.440 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Operating Voltage
19.26 ac volts nominal single component single secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Maximum Operating Temp
130.0 deg celsius
-
Cubic Measure (Non-Core)
3.584 cubic inches
-
Body Width
1.030 inches maximum
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
7 turret
-
Body Height
1.160 inches maximum
-
Thread Direction (Non-Core)
err-070
-
Winding Power Rating
30.0 watts single component single secondary
-
Nominal Thread Size
0.138 inches single group
-
Overall Height
1.500 inches nominal