Technical Characteristics

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Bushing Length

    0.625 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Radius

    0.656 inches nominal

  • Nonturn Device Length

    0.130 inches nominal

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Unpackaged Unit Weight

    3.000 ounces

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    2a single pole type

  • Body Length

    2.000 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • End Item Identification

    2350-01-089-1261

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.620 minimum at 200 pct and 8.000 maximum at 200 pct single location

  • Switch Terminal Type

    pin

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.