APGN-6-1REC3-9387-6
Circuit Breakers
CIRCUIT BREAKER
APGN-6-1REC3-9387-6
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Pitch Diameters
+0.4752/+0.4787 inches
-
Bushing Length
0.625 inches nominal
-
Body Width
0.750 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Nonturn Device Location
at 12 oclock
-
Nonturn Device Radius
0.656 inches nominal
-
Nonturn Device Length
0.130 inches nominal
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Trip Release Method
magnetic-hydraulic single location
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Switch Location And Position Designation
internal at pole one
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Unpackaged Unit Weight
3.000 ounces
-
Thread Series Designator
un
-
Terminal Type And Quantity
2 tab w/screw
-
Body Style
2a single pole type
-
Body Length
2.000 inches nominal
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
End Item Identification
2350-01-089-1261
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.500 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.620 minimum at 200 pct and 8.000 maximum at 200 pct single location
-
Switch Terminal Type
pin
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc