13084378

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

13084378

5915-01-175-8327

5915 - Filters and Networks

Lockheed Martin Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Maximum Voltage Drop Per Function

    0.56 volts dc 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Body Height

    1.000 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Length

    2.000 inches nominal

  • Special Features

    function 5 consists of one notch filter

  • Operating Current Rating Per Function In Amps

    0.25 1st radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 4th radio interference 4th function

  • Functional Terminal Type And Quantity

    6 wire lead output 2nd function

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Temp Rise

    20.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Operating Current Rating Per Function In Amps

    0.35 6th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.380 inches nominal

  • Operating Current Rating Per Function In Amps

    0.35 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Body Width

    2.000 inches nominal

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference 3rd function

  • End Item Identification

    1270-01-142-2855 target designator

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference 6th function

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 5th radio interference 5th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Unthreaded Mounting Hole Diameter

    0.187 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.25 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    0.25 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Functional Terminal Type And Quantity

    6 wire hook input 1st function

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Operating Current Rating Per Function In Amps

    0.1 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Maximum Voltage Drop Per Function

    2.3 volts ac 4th radio interference

  • Unpackaged Unit Weight

    5.700 ounces

  • Maximum Voltage Drop Per Function

    2.3 volts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    2.3 volts ac 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Maximum Voltage Drop Per Function

    2.3 volts ac 1st radio interference

  • Maximum Voltage Drop Per Function

    0.56 volts dc 6th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...